Little Swan UB1000 P6 China Business Trip Report — Zeiss EVO 18 SEM (2018-05-10)

UB1000_P6 setup business trip report for Zeiss EVO 18 SEM at Little Swan. Trip date 2018.05.10; report written 2018.05.14; engineer CHOI SUNG WON. VC-Class summary table (ACTIVE Base Z C / Top E; X and Y E/E), installation results narrative, internal-program Z/X/Y ACTIVE transmissibility plots, and floor vibration-environment Z/X/Y 1/3-octave plots. Decorative header PNG omitted.

Tier-1 Semiconductor Bruker VERTEX 80 DVIA-U1000 (UO1000_P5) Installation Report — Seoul

DVIA-U1000 compact worksheet UO1000_P5 for Bruker VERTEX 80 at Tier-1 Semiconductor (Seoul Samsung Hospital B4 animal laboratory). Business trip and report written 18.02.06; operator Hyungmoon Choi. VC-Class summary table (building floor vs isolator top plate) and follow-up notes per the form; MB1000 internal-program and octave-band (floor vs isolator top) Z/X/Y screenshots per §2a embed mapping. Decorative header bitmap (image1) omitted.

Saeron Technology UB1000 P3 demo result — in-house SEM vibration survey (2016-10-21)

Demo report dated 21 October 2016 for UB1000 P3 at Saeron Technology in Uiwang, Gyeonggi-do, comparing on-site vibration and 100,000× SEM imaging against the existing MB1000 platform on an in-house SEM. Travelers CHOI HYOUNGMUN and LIM JONG UK; measurer LIM JONG UK. Publication includes the in-house SEM photograph, floor versus platform VC-class Z/X/Y plots, and ACTIVE image-comparison captures for MB1000 and UB1000. Decorative header PNG omitted.

DVIA-U type (UB1000) Installation Test Report — Reporting 2016.09.02

Archived DVIA-U type UB1000 installation test summary (installation and measurement 2016.08.31; reporting 2016.09.02; engineer LIM JONG UK, DAEIL SYSTEMS). Source worksheet lists VC-class results for active Z/X/Y on base and top and includes internal-program transmissibility plots (Result 1) plus PULSE 1/3 octave band plots (Result 2). No customer or installation site is named in the worksheet.

UB1000 P2 Chengdu China Business Trip Report — Zeiss EVO 18 SEM (2016-09-02)

UB1000_P2 setup business trip to Chengdu, China (30 Aug–1 Sep 2016) for Zeiss EVO 18 SEM. Engineers CHOI HYOUNGMUN and LIM JONG UK; report written 2016-09-02. Publication includes the equipment setup photograph, passive spring comparison diagram, internal-program Z (PASSIVE/ACTIVE) and X/Y ACTIVE plots, floor vibration-environment Z/X/Y plots, and SEM ON/OFF comparison plots (OFF captures only; ON reuses ACTIVE transmissibility plots from Attachment 1). Decorative header PNG omitted.

Korea Institute of Ocean Science & Technology UD350 DVIA-UD350 Setup Result Report

2016 DVIA-UD350 setup report for Korea Institute of Ocean Science & Technology: ACTIVE-state VC-Class summary table (ship environment), excursion notes referencing three attachment groups, plus internal-program screenshots, vibration-environment plots, and floor time-axis graphs (Z/X/Y). Decorative DOCX title-block image (image1) omitted from publication.