본문으로 바로가기
설치 보고서
DVIA-M Series
06-10-2021

Inner Mongolia University Hitachi S4800 DVIA-MB1000 remote VEC (201216R1-1 / P209) — 2021.06.10

DVIA-M Series
Installation Report
VEC
Remote
DVIA-MB1000
YIMO
Inner Mongolia University
Hitachi
S4800
201216R1-1
P209

MB1000_201216R1-1 (P209) Set up

대상 장비Hitachi S4800
설치 장소NeiMengGu
비고Good Performance
엔드 유저内蒙古大学
Operator: Munho NohDate of business trip : 17.12.27~17.12.29
Date of setup : 21.06.10
Date of reporting : 21.06.10

개요

After Active mounting, measure the vibration environment to check that there is no problem in using the equipment.

Measurement date: 21.06.10 (THU)

Operator: Daeil System, Research engineer Munho Noh

Place of measurement : NeiMengGu

Equipment Model: Hitachi S4800

Measurement conditions and results

Summary of measurement results

Test Condition — Transmissibility

2 Hz5 Hz10 Hz
Z-23.43 dB-23.72 dB-31.29 dB
X-32.97 dB-36.24 dB-44.94 dB
Y-37.12 dB-38.61 dB-42.15 dB

Good omnidirectional performance.

MB1000 internal program performance measurement result

Z축

X축

Y축

이 케이스 스터디 공유하기