설치 보고서
DVIA-M Series
06-18-2021
Shihu Technology Nanjing SUSS MA/BA Gen4 Pro DVIA-MB1000 — Remote setup — 2021.06.18
DVIA-M Series
Installation Report
DVIA-MB1000
Shihu Technology
Nanjing
SUSS
210316R5
P229
목차
(MB1000_210316R5(P229) Set up)
| Target equipment | BOND ALINGER/ SUSS MA/BA Gen4 Pro |
|---|---|
| Place of installation | Nanjing, China (Ground floor, lab) |
| Remark | Good Performance |
| END USER | Shihu Technology(Nanjing) Co., Ltd. |
Operator: Doohyun Kim
Date of setup : 21.06.18
Date of reporting : 21.06.18
Date of business trip : 17.12.27~17.12.29
개요
After Active mounting, measure the vibration environment to check that there is no problem in using the equipment.
Measurement date: 21.06.18 (FRI)
Operator: Daeil System, Research engineer Doohyun Kim
Place of measurement : Nanjing, China (Ground floor, lab)
Equipment Model: BOND ALINGER / SUSS MA/BA Gen4 Pro
측정 조건 및 결과
Summary of measurement results
Test Condition
Transmissibility
| Transmissibility | 2 Hz | 5 Hz | 10 Hz |
|---|---|---|---|
| Z | -27 dB | -20 dB | -30 dB |
| X | -25 dB | -23 dB | -30 dB |
| Y | -16 dB | -30 dB | -38 dB |
Good omnidirectional performance.
MB1000 internal program performance measurement result
Z축
X축
Y축
이 케이스 스터디 공유하기
케이스 스터디 정보
카테고리
설치 보고서
시리즈DVIA-M Series
작성일06-18-2021
태그
DVIA-M Series
Installation Report
DVIA-MB1000
Shihu Technology
Nanjing
SUSS
210316R5
P229
관련 케이스 스터디

DVIA-M Series
ZEISS Sigma 300 VP DVIA-MB1000 (220121R3) Shanghai Installation Report
05-16-2026자세히

DVIA-M Series
SNU Precision DUAL BEAM DVIA-MB1000 (220216R3) Installation Report
05-16-2026자세히

DVIA-M Series
ZOLIX Shanghai Institute of Technology and Technology Three-axis Vibration Exciter DVIA-MB1000 (220330R5-3) Installation Report
05-16-2026자세히