본문으로 바로가기
설치 보고서
DVIA-M Series
11-19-2020

ZOLIX DVIA-MO1000 (200914R2, P206) Remote Tuning Installation Report — November 19, 2020

DVIA-M Series
Installation Report
ZOLIX
MO1000
DVIA-MO1000
P206
200914R2
Remote tuning

MO1000_200914R2(P206) Set up

대상 장비 및 설치 장소

Target equipmentDummy
Place of installationZolix
RemarkGood Performance
END USERZolix

보고 일정

Operator: Munho Noh

Date of setup : 20.11.19

Date of reporting : 20.11.19

Date of business trip : 17.12.27~17.12.29

개요

After Active mounting, measure the vibration environment to check that there is no problem in using the equipment.

Measurement date: 20.11.19 (THU)

Operator: Daeil System, Research engineer Munho Noh

Place of measurement : Zolix

Equipment Model: Dummy

측정 조건 및 결과

측정 결과 요약

Test Condition

Transmissibility

2 Hz5 Hz10 Hz
Z-23.26 dB-35.17 dB-31.86 dB
X-25.05 dB-39.73 dB-39.34 dB
Y-26.68 dB-35.11 dB-37.07 dB

Good omnidirectional performance.

@30 Hz / Z : -34.31 dB / X : -46.96 dB / Y : -37.08 dB

MB1000 내부 프로그램 성능 측정 결과

Z축

X축

Y축

이 케이스 스터디 공유하기

케이스 스터디 정보

카테고리
설치 보고서
시리즈DVIA-M Series
작성일11-19-2020
태그
DVIA-M Series
Installation Report
ZOLIX
MO1000
DVIA-MO1000
P206
200914R2
Remote tuning