DVIA-M type (MB1000) Installation test — NEMO — 2015-09-03
목차
설치·측정·보고 일자 및 담당자
Installation & Mesurement Date : 2015.09.01.
Reporting Date : 2015.09.03.
DAEIL SYSTEMS
LIM JONG UK
설치 결과 요약
※ Installation Results Summary
| 방향 | 바닥 VC-Class | 플랫폼(Active) VC-Class |
|---|---|---|
| Z | B | D |
| X | E | G |
| Y | D | F |
Good performance in all directions.
Vertical axis Z is B Class, the horizontal axis X is E Class, the horizontal axis Y is D Class. It was measured vibration environment in floor.
Vertical axis Z is D Class, the horizontal axis X is G Class, the horizontal axis Y is F Class. It was measured vibration environment in top of Active state.
Use the internal programs as a result of performance measurement, such as red circles and marked the peak occurs but is thought to power supply noise.
Used data of internal program to making performance graph, show "Result 1".
Used first data of PULSE to making performance graph, Show "Result 2".
Used second data of PULSE to making performance graph, Show "Result 3".
결과 1 — 성능 그래프(내부 프로그램, Transmissibility)
결과 1 — Z축
결과 1 — X축
결과 1 — Y축
결과 2 — 성능 그래프(PULSE, 첫 번째 데이터 — 1/3 옥타브 대역)
결과 2 — Z축
결과 2 — X축
결과 2 — Y축
결과 3 — 성능 그래프(PULSE, 두 번째 데이터 — 1/3 옥타브 대역)
결과 3 — Z축
결과 3 — X축
결과 3 — Y축