Tier-1 Semiconductor Hwaseong Hitachi CG6300 DVIA-P4000 Installation Report
DVIA-P Series
Installation Report
Tier-1 Semiconductor
Hwaseong
Hitachi
CG6300
220126R3
Contents
개요
보고 대상: Tier-1 Semiconductor
The DVIA-P4000 active vibration isolation platform is appropriately installed and functioning as intended.
시스템 정보
모델: DVIA-P4000
시리얼 넘버: 220126R3
엔지니어
Engineer: Youngha Lee
Tuning date: 22.05.27
Report written date: 22.05.30
Date of business trip : 17.12.27~17.12.29
Youngha Lee from DAEIL SYSTEMS
튜닝 일자
May 27, 2022
설치 위치
Tier-1 Semiconductor Hwaseong V1 Line 10F
장비
Hitachi CG6300
진동 결과 요약
| 측정 지점 | Z축(수직) 1-10 Hz | Z축(수직) 10-80 Hz | X축(좌-우) 1-10 Hz | X축(좌-우) 10-80 Hz | Y축(전-후) 1-10 Hz | Y축(전-후) 10-80 Hz |
|---|---|---|---|---|---|---|
| Floor | B | B | C | C | B | A |
| Active | D | D | D | D | D | C |
데이터 및 이미지
Z-axis (Vertical) VC curves
Floor
On active vibration isolation platform
X-axis (Left to Right) VC curves
Floor
On active vibration isolation platform
Y-axis (Front to Back) VC curves
Floor
Above Active isolator
참조
Generic Vibration Criteria
참고:
1. VC-A/B is measured in 1/3 octave bands from 8-80 Hz, VC-C through VC-G from 1-80 Hz.
2. Detail size refers to line widths in microelectronics manufacturing or particle sizes in medical research.
이 케이스 스터디 공유하기
케이스 스터디 정보
카테고리
설치 보고서
시리즈DVIA-P Series
작성일05-21-2026
태그
DVIA-P Series
Installation Report
Tier-1 Semiconductor
Hwaseong
Hitachi
CG6300
220126R3
관련 케이스 스터디
DVIA-P Series
Tier-1 Semiconductor Hwaseong Hitachi CG6300 DVIA-P7000 Installation Report
05-27-2022자세히

DVIA-P Series
Yimo Tech Hitachi CG6300 DVIA-P4000 (220126R3) Installation Report
05-21-2026자세히
DVIA-P Series
Tier-1 Semiconductor Hwaseong NRD Line AlMs 1x DVIA-P4000 (220804R2) Installation Report
05-21-2026자세히